OVICTOR GROUP CO.,LTD

Magnetic Float Ball Level Gauge

/
Magnetic Float Ball Level Gauge

Magnetic Float Ball Level Gauge

Floating ball Magnetic Level Gauge

Float Cage Material: PTFE, PP, PVC, PVDF

Max. Centre to Centre Distance: 6000 mm, greater lengths on request
Connecting Flanges: According to DIN or ANSI B16.5
Rated Pressure: <10.0 Mpa for SS & 0.3 Mpa for PP, PVC & PVDF(Higher pressure rating can also be provided)
Temperature of Liquid: 450ºC (Max.) for SS, 80ºC (Max.) for PVDF,60ºC (Max.) for PVC, 50ºC (Max.) for PP
Specific Gravity: Min. 0.40g/cm³
Signal: 4~20mA.DC、4~20mA.DC+Hart、pulse、RS485
Switch type: NO、NC、SPDT
Explosion-proof mark: Exd II BT6
Protection Grade: IP65/IP67

OVICTOR Magnetic Float Ball Level Gauge provides clear, high clarity indication of liquid level. Magnetic Float Ball Level Gauge are principally designed as an alternative to glass level gauges.
Magnetic float ball level gauge is consists of three major components: Float Chamber, Float and Indicator System. It operates on the principle of magnetic field coupling to provide fluid level information. Float chamber is typically constructed with non magnetic pipe having process connections that matches to the vessel connections. Float size and weight is determined by the process fluid, pressure, temperature and the specific gravity of the process fluid. Float contains magnets to provide 360o magnetic flux field. Magnetic float ball level gauge have top-bottom, top and side mounting structures, with two types of display systems, namely capsules and two-color rollers.

Common models that OVICTOR can provide:

1. Basic model:
Suitable for level measurement of liquid medium which working pressure less than 4.0MPa, and working temperature lower than 200℃.
2. Anti-corrosion model:
It’s suitable for acid, alkali and many organic solvents. It use PTFE lined stainless steel, PPR, PVC as body material.
3. Jacketed model:
Applied to antifreeze, insulation and heating level measurement occasions. Jacket type: steam jacket, water cycle jacket, vacuum jacket, electric heating jacket, and electric warming jacket.
4. High temperature high pressure model:
It’s suitable for high temperature and high pressure level measurement occasions. The maximum process temperature is 520℃. The maximum working pressure is 32MPa.

Products Feature
  • Highly visible level indication.
  • Float designed and weighted for maximum accuracy with 75 grams minimum upward buoyant force.
  • Transmitter and switch options which can be installed, adjusted and maintained with no process interruption.
  • Safe for corrosive, flammable, toxic, high-temperature and high-pressure applications.
  • Rugged design – low or no maintenance.

Specification of Magnetic Float Ball Level Gauge

Float Cage Material

SS304, SS316, PTFE, PP, PVC, PVDF

Scale

Graduated in cm, Aluminium or SS304
Max. Centre to Centre  Distance

100-15000mm

Rated Pressure

<10.0 Mpa for SS;  0.3 Mpa for PP, PVC & PVDF
Higher pressure rating can also be provided
Temperature of Liquid

450ºC (Max.) for SS;  80ºC (Max.) for PVDF;
60ºC (Max.) for PVC; 50ºC (Max.) for PP;

Specific Gravity

Min. 0.40g/cm³
Signal

4~20mA.DC、pulse、RS485

Switch type

NO、NC、SPDT
Measuring Accuracy

+/- 5 mm

Connecting Flanges

According to DIN, ANSI or JIS
Installation Methods

side-mounted, top-mounted

Explosion-proof Mark

Exd II BT6
Protection Grade

IP65/IP67

 

 

Product Related

滚动至顶部